Talley Quattro Acute Mattress Replacement System (PR03210)
Talley Quattro Mattress Replacement
https://ilcaustralia.org.au/products/3210
An electrically operated, static low pressure or alternating air, mattress replacement system. Designed for pressure reduction in high risk users (supplier stated). Suitable for users in acute hospital settings. Available in single and cot size.
General Details
- Cleaning Requirements
The mattress replacement system and cover are highly resistant to soaps and detergents and are fully launderable.
- Extra product information
The system consists of a portable pump unit and a mattress made from polyurethane that replaces an existing mattress.
The Talley Quattro Acute Mattress Replacement System is comprised of 27 individual cells that have a 1 in 4 cell cycle. The alternating cycle time can be modified.
The cells are replaceable and fully repairable. The cover is two way stretch, vapour permeable, waterproof and flame retardant. Both the cell material and the cover are non allergenic.Additional features include:
* active alternating pressure mode or static low pressure mode
* adjustable air cycle time and air pressure
* maximum inflation mode to maintain maximum static pressure for up-to 15 minutes
* audible and visual operation status and fault indicators
* CPR facility for rapid deflation to enable CPR procedures
* transport mode which allows the user to remain supported without power for up to 12 hours.- Maintenance
Check the mattress daily for punctures or air loss.
In the event of failure of air cells to inflate or "low pressure fault" on display, check:
* power source is on / functional
* mattress is connected to pump and not in Transport Mode (green dot visible)
* CPR valve is closed
* air cells are all connected and nil punctures.Contact service centre / supplier for issues arising with pump or damage to air cells. Individual air cells can be removed for repair or replacement.
- Safety and Usage Advice
SAFETY FEATURES: visual and audible operation status, such as a low air pressure warning alarm, and fault indicators on the pump.
CPR RELEASE: situated at the side of the overlay for rapid deflation. Note that the yellow CPR tag is an indicator, not the CPR release (which is a dial situated on the head end of the right side of the mattress).
IN THE EVENT OF POWER FAILURE:
* unplanned power failure - disconnect the hose from the pump to put mattress into Transport Mode. This will lock the valve. The mattress will remain inflated for approximately 12-15 hours (depending on weight).
* planned power failure - inflate to maximum using the Max. Inflation function - this will extend time of inflation without power up to 24 hours (depending on weight).- Caution: Pressure Cushions & Mattresses
• All pressure reduction products must be monitored to prevent 'bottoming out'. This occurs when the user's weight bears down so hard on the product material that it is flattened and the bony parts are pressed against the surface below the cushion or mattress. Where bottoming out occurs even with correct use (e.g. correct inflation levels), a different product may need to be considered.
• Sometimes, due to the user deteriorating, the product may become unsuitable. Continuous monitoring is necessary and alternative products may be recommended.
• There are many things to consider when selecting pressure care products including nutrition, skin moisture, level of mobility, age shear, friction, location of pressure ulcer (if present) and hygiene. Any comments regarding level of pressure care is a suggestion made by suppliers as a guide to assist with selection, and this may differ from brand to brand. When selecting pressure care products it is strongly advised that a comprehensive assessment is undertaken by a health professional to encourage correct product selection and monitoring of product effectiveness
- Manufacturer/Country
- Talley / United Kingdom
Models / Specifications
- Model Standard: Standard
-
- Width 880 mm
- Length 1980 mm
- Depth 240 mm
- Weight 12.5 kg
- Load Capacity (supplier stated) 250 kg
- Model Pump: Pump
-
- Depth 165 mm
- Weight 3.4 kg
- Height Overall 233 mm
- Width 355 mm
- Model Paediatric: Paediatric
-
- Width 620 mm
- Length 1310 mm
- Depth 180 mm
- Weight 5.8 kg
- Load Capacity (supplier stated) 95 kg
Suppliers (0)
Agents (0)
Importers (0)
Manufacturers (0)
Maintenance
Refer to the supplier and manufacturer manual for maintenance instructions and safety warnings.
Standards
Some assistive technology needs to meet Australian or other standards. Standards may relate to materials, manufacturing, and installation. Products that meet Australian or international standards will have written certification. To find out if a product meets Australian Standards ask the supplier to show you the certificate. For more information about standards see http://www.ilcaustralia.org.au/Using_Assistive_Technology/standards_regulation
Disclaimer
Independent Living Centres Australia (ILCA) does not design or make products. ILCA cannot guarantee that all information given is correct. Prices shown are a rough guide. Some products may incur GST. Check with suppliers for up-to-date prices. The display of products at an ILCA centre, or details given in print, is only for your information. It is not a recommendation. You should always get professional advice when choosing products. The person choosing the product is responsible for their choice. ILCA takes no responsibility for people choosing equipment or services which will cause (or be alleged to have caused) loss or injury. You must follow the manufacturer’s or service provider’s instructions when using equipment or services.